Gann Hydromette UNI 2, #30001550
Gann Hydromette UNI 2, #30001550
-> The Hydromette UNI 2 is also available as a set, please click here!
The UNI 2 is an electronic and universal triple measuring instrument to which a wide range of (active) electrodes can be connected. The measuring ranges building moisture, humidity and temperature can be measured.
In addition, all building moisture measuring electrodes based on the resistance measuring principle can be connected.
The following (active) electrodes can be connected:
- B 50, B 60 and LB 71 for non-destructive moisture measurement and indication in ceilings, walls, floors and other building materials.
- Infrared surface temperature sensor IR 40 EL, #31003150 for measuring surface temperature, thermal bridges and dew point temperature
- Active electrode RF-T 28 EL, ##31003155, Active electrode RH-T 37 EL 320, #31003141 and Active electrode RH-T 37 EL flex 250, #31003142 for air humidity and air temperature measurement and
- all our Pt 100 temperature sensors
The measuring device is particularly suitable for air-conditioning technicians, water damage specialists, insurance companies and as a supplement to a wood moisture measuring device.
Measuring range of the Gann Hydromette UNI 2
Building moisture:
for resistance-based measurements: (*)
0 - 80 digits
0.3 - 25 wt.% resp. 0.3 - 12 CM-%
for capacitive measurements: (*)
0 - 199 digits (scan range)
0.3 - 8.5 wt.% or 0.3 - 6.5 CM-% with B 50, B 60 and LB 70
2 - 8 wt.% with MB 35 on concrete surfaces
Measurement of the rel. humidity in the borehole*:
5 - 98 % r.h. resp.
0.2 - 3.7 % by weight with RH-T 37 EL and RH-T 37 EL flex
Wood moisture content:
40 - 200 % (atro) with MH 34 on softwood.
Air humidity:
5 - 98 % r.h. with RF-T 28, RH-T 37 EL and RH-T 37 EL flex
Temperature:
-200 - +600 °C depending on Pt 100 temperature sensor.
Infrared measuring range:
-20 - +199.9 °C with IR 40 EL
*= Humidity conversion in % depending on the building material via conversion table
Accessories for the Gann Hydromette UNI
Download instructions Hydromette UNI 2Building moisture:
- Impact electrode M 20 (3300) (Einschlag-Elektrode M 20 (3300))
- Insertion electrode M 19 (3400) (Einstech-Elektrode M 19 (3400))
- Insertion electrode pair M 6 (3700) (Plug-in electrode pair M 6, #31003700)
- Depth measuring electrode pair M 21-100 (3200) (Depth measuring electrode pair M 21-100, #31003200)
- Depth-measuring electrode pair M 21-250 (3250) (Depth measuring electrode pair M 21-250, #31003250)
- Pair of brush electrodes M 25-100 (3740) (Brush-electrode pair M 25-100, #31003740)
- Brush-electrode pair M 25-300 (3743) (Brush-electrode pair M 25-300, #31003743)
- Gann active electrode B 50 (3750) (Gann Aktiv-Elektrode B 50 (3750))
- Gann active electrode B 60 (3760) (Gann Aktiv-Elektrode B 60 (3760))
- Gann active electrode LB 71 (3765) (Gann Aktiv-Elektrode LB 71 (3765))
Air humidity:
- Gann active electrode RF-T 28 EL (3155) (Gann Aktiv-Elektrode RF-T 28 EL (3155))
- Gann active electrode RH-T 37 EL 160 (3140) (Gann Aktiv-Elektrode RH-T 37 EL 160 (3140))
- Gann active electrode RH-T 37 EL 320 (3141) (Gann Aktiv-Elektrode RH-T 37 EL 320 (3141))
- Gann active electrode RH-T 37 EL flex 250 (3142) (Gann Aktiv-Elektrode RH-T 37 EL flex 250 (3142))
- Gann active electrode RH-T 37 EL flex 350 (3143) (Gann Aktiv-Elektrode RH-T 37 EL flex 350 (3143))
Air temperature:
- Gann active electrode RF-T 28 EL (3155) (Gann Aktiv-Elektrode RF-T 28 EL (3155))
- Gann active electrode RH-T 37 EL 160 (3140) (Gann Aktiv-Elektrode RH-T 37 EL 160 (3140))
- Gann active electrode RH-T 37 EL 320 (3141) (Gann Aktiv-Elektrode RH-T 37 EL 320 (3141))
- Gann active electrode RH-T 37 EL flex 250 (3142) (Gann Aktiv-Elektrode RH-T 37 EL flex 250 (3142))
- Gann active electrode RH-T 37 EL flex 350 (3143) (Gann Aktiv-Elektrode RH-T 37 EL flex 350 (3143))
- Gann air/gas temperature sensor LT 20 (3190) (Gann Luft-/Gas-Temperaturfühler LT 20 (3190))
Material temperature:
- Gann piercing temperature sensor ET 10 (3165) (Gann Einstech-Temperaturfühler ET 10 (3165))
- Gann immersion and flue gas temperature sensor TT 40 (3180) (Gann Tauch- und Rauchgas-Temperaturfühler TT 40 (3180))
- Gann immersion and flue gas temperature sensor TT 30 (3185) (Gann Tauch- und Rauchgas-Temperaturfühler TT 30 (3185))
- Gann immersion temperature sensor ET 50 (3160) (Gann Einstech-Temperaturfühler ET 50 (3160))
- Gann immersion and flue gas temperature sensor TT 480 (3181) (Gann Tauch- und Rauchgas-Temperaturfühler TT 480 (3181))
- Gann immersion and flue gas temperature sensor TT 600 (3182) (Gann Tauch- und Rauchgas-Temperaturfühler TT 600 (3182))
- Gann flexible temperature sensor FT 2 (3195) (Gann Flexibler Temperaturfühler FT 2 (3195))
- Gann flexible temperature sensor FT 5 (3196) (Gann Flexibler Temperaturfühler FT 5 (3196))
- Gann flexible temperature sensor FT 10 (3197) (Flexible temperature sensor FT 10, #31003197)
- Gann flexible temperature sensor FT 20 (3198) (Gann Flexibler Temperaturfühler FT 20 (3198))
- Gann Flexible Temperature Sensor FT 30 (3199) (Flexible temperature sensor FT 30, #31003199)
Surface temperature:
- Gann Infrared Surface Temperature Sensor IR 40 EL (3150) (Infrared surface temperature sensor IR 40 EL, #31003150)
- Gann surface temperature sensor OTW 90 (3175) (Surface temperature sensor OTW 90, #31003175)
- Gann surface temperature sensor OT 100 (3170) (Surface temperature sensor OT 100, #31003170)
- Gann surface temperature sensor OTW 480 (3176) (Surface temperature sensor OTW 480, #31003176)
Other accessories:
- Stand-by case BK 14-I (5061) (Gann stand-by case BK 14-I, #31005061)
- Stand-by case BK 14-II (5062) (Gann stand-by case BK 14-II, #31005062)
- Gann test adapter temperature (6072) (Gann test adapter temperature, #31006072)
- Test adapter building moisture (6071) (Gann test adapter building moisture, #31006071)
- Measuring cable MK 8 (6210) (Gann measuring cable MK 8, #31006210)
- Gann measuring cable MK 15 (6710) (Gann measuring cable MK 15, #31006710)
- BNC adapter (6050) (Gann BNC adapter, #31006050)